The performance test of several coagulant used to deal with integrated pulp and paper wastewater |
BAI Li1, GAO Wu-long2 |
1. Guangdong Provincial Environmental Monitoring Center, Guangdong, Guangzhou 510045, China; 2. Environmental Technology Center, Zhongshan City, Guangdong, Zhongshan 528402, China |
|
|
Abstract This article compares the treatment effect of a series of coagulation tests,by changing the test conditions,and using a new type polymer coagulant,aluminum sulfate and PAC on wood-based pulp and paper mills integrated wastewater treatment. The experimental results show that at the best pH value and dosage conditions new polymer coagulant integrated pulp and paper deals with the waste water relatively the best.When pH is 8.29 and dosage is 175 mg·L-1,even if CPAM is not added,the removal rate of COD,turbidity,chroma is 87.4%,96.4% and 89.5%.COD and chroma of the effluent are 90 mg·L-1 and 32 times respectively,which can meet the first grade of secondary period of Local Standard Discharge Limits of Water Pollutants of Guangdong Province(DB 44/26-2001).
|
Received: 25 August 2009
|
|
|
|
|
[1] 刘春,张安龙,文志贵.2009.光催化氧化技术处理制浆造纸漂白废水[J].湖北造纸,(02):35-37.
[2] Stina Karlsson,Bjarne Holmbom,Peter Spetz,et al.2001.Reactivity of Trarnetes laceases with fatty and resin acids[J].Applied Microbiology and Biotechnology,55(3):317~320.
[3] 高洪贵,谢益民,孙媛芳.2008.Fe-CA仿酶-混凝法处理造纸综合废水[J].造纸科学与技术,(03).10-12.
[4] 周丹,乎世斌,张涛.2004.Fenton-混凝法处理造纸废水的试验研究[J].环境科学与技术,(01):7-8.
[5] 于淼,梁娜,宋志文.2009.制浆造纸废水的处理及回用[J].西南给排水,(01):22-25.
[6] Pierre Le-Clech,Eun-Kyung Lee,Vicki Chen.2006.Hybrid photo-catalysis/membrane treatment for surface waters containing low concentrations of natural organic matters[J].Water Research,410:323-330.
[7] 唐受印,戴友之.2000.水处理工程师手册[M].北京:化学工业出版社.118-119. |
[1] |
. [J]. , 2014, 33(6): 1085-1090. |
|
|
|
|