Aerobic activated sludge-stabilization pond process for piggery wastewater treatment at Zhongluotan Lean Swine Breeding Farm |
GAO Yun-Chao1, KUANG Zhe-Shi1, TIN Xing-Shan1, DU Zhong-Liang2, YANG Jing-Pei2 |
1. Biotechnological Research Institute, Guangzhou 510640, China; 2. Lean Swine Breeding Center, Guangdong Academy of Agricultural Sciences, Guangzhou 510640, China |
|
|
Abstract 150 tons of sewage of which the COD was usually above 15 000mg·L-1 was discharged from Lean Swine Breeding Center of Guangdong Academy of Agricultural Sciences for one day. Aerobic activated sludge-stabilization pond method was used to treat the sewage from the piggery. The raw sewage flowed through the coarse sieve screen, fine sieve screen, hydrolytic acidulation tank, primary settling tank, aeration tank, final settling tank and stabilization pond. The sludge was transported to the dewatering tank for desiccation. The total area of aerobic activated sludge treatment is about 150m×50m, and the stabilization pond sized 6 000 m2. The treated sewage from stabilization pond achieves the Second Class Drainage Standard according to "The National Standard of Wastewater Overall Drainage (GB8978-88)" and can be used to irrigate for rice and other vegetable field directly.
|
Received: 25 February 2003
|
|
|
|
|
[1] 广东省农村统计年鉴编纂委员会.2002.广东农村统计年鉴[M].北京:中国统计出版社.271-275.
[2] 国家环保局"水和污水检测分析方法"编委会.1998.水和污水检测分析方法[M].第三版,北京:中国环境科学出版社.354-366.
[3] 韩洪军.2002.污水处理构筑物设计与计算[M].哈尔滨:哈尔滨工业大学出版社.30-198.
[4] 张自杰.2001.排水工程[M].北京:中国建筑工业出版社.54-197.
[5] 中国市政工程西北设计研究院.2002.常用设备(给水排水设计手册第11册)[M].第二版,北京:中国建筑工业出版社.99. |
[1] |
. [J]. , 2015, 34(3): 116-121. |
|
|
|
|